Method of indirect measurement of oxygen concentration in the air

User Rating:  / 1
PoorBest 

Authors:

A.O.Zaporozhets, Cand. Sc. (Tech.), orcid.org/0000-0002-0704-4116, Institute of Engineering Thermophysics of NAS of Ukraine, Kiev, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

O.O.Redko, orcid.org/0000-0002-9054-5746, National Aviation University, Kyiv, Ukraine

V.P.Babak, Corr. Member of the NAS of Ukraine, Dr. Sc. (Tech.), Prof., orcid.org/0000-0002-9066-4307, Institute of Engineering Thermophysics of NAS of Ukraine, Kiev, Ukraine, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

V.S.Eremenko, Dr. Sc. (Tech.), Assoc. Prof., orcid.org/0000-0002-4330-7518, National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, Kyiv, Ukraine

V.M.Mokiychuk, Cand. Sc. (Tech.), Assoc. Prof., orcid.org/0000-0002-2309-9555, National Aviation University, Kyiv, Ukraine

Abstract:

Purpose. Determination of a functional relationship between the oxygen concentration in the air and meteorological parameters (temperature, pressure, humidity) in open areas.

Methodology. The functional relationship between the oxygen concentration in the air and meteorological parameters is established on the basis of experimental gas laws. Approximating functions of the oxygen volume concentration changing in the air are obtained using mathematical statistics methods. The correction for the determination of the excess air ratio was determined on the basis of the theory of errors. Forecasting the oxygen volume concentration in the air was carried out on the basis of the inverse functional dependence established by means of the discrete Fourier transform.

Findings. Approaches to measuring and predicting the oxygen volume concentration in the air based on meteorological parameters are substantiated.

Originality. A method has been developed for determining the air gas concentration based on meteorological parameters of the environment. The method for determining the excess air ratio as an informative parameter for controlling the fuel combustion has been improved. A method for predicting the oxygen volume concentration in the air based on the discrete Fourier transform is proposed.

Practical value. Technical solutions are proposed and new methods and means of measuring the oxygen volume concentration in the air are developed, including those for improving the accuracy of determining the excess air ratio during the fuel burning in boilers. Also, the obtained results can be applied in different areas of medicine, ecology, agro-industrial sector, and others.

References.

1. Xu, W., Song, W., Zhang, Y., Liu, X., Zhang, L., Zhao, Y., Liu, D., Tang, A., Yang, D., Wang, D., Wen, Z., Pan, Y., Fowler, D., Collet Jr., J. L., Erisman, J. W., Goulding, K., Li, Y. and Zhang, F., 2017. Air quality improvement in a megacity: implications from 2015 Beijing Parade Blue pollution control actions. Atmospheric Chemistry and Physics, 17(1), pp. 31‒46.DOI: 10.5194/acp-17-31-2017.

2. Chapman, L., Bell, C. and Bell, S., 2017. Can the crowdsourcing data paradigm take atmospheric science to a new level? A case study of the urban heat island of London quantified using Netatmo weather stations. International Journal of Climatology, 37(9), pp. 3597‒3605. DOI: 10.1002/joc.4940.

3. De Vos, L., Leijnse, H., Overeem, A. and Uijlenhoet, R., 2017. The potential of urban rainfall monitoring with crowdsourced automatic weather stations in Amsterdam. Hydrology and Earth System Sciences, 21(2), pp. 765‒777. DOI: 10.5194/hess-21-765-2017.

4. Meier, F., Fenner, D., Grassmann, T., Otto, M. and Scherer, D., 2017. Crowdsourcing air temperature from citizen weather stations for urban climate research. Urban Climate, 19, pp. 170‒191. DOI: 10.1016/j.uclim.2017. 01.006.

5. Valipour, M., 2017. Analysis of potential evapotranspiration using limited weather data. Applied Water Science, 7(1), pp. 187‒197. DOI: 10.1007/s1320.

6. Pope, F., Chapman, L., Fisher, P., Mahmood, M., Sangkharat, K., Thomas, N. and Thornes, J., 2017. Resilience of urban ambulance services under future climate, meteorology and air pollution scenarios. In: EGU General Assembly Conference Abstracts[online], 19, p. 17757. Available at: <http://adsabs.harvard.edu/abs/ 2017EGUGA.1917757P>[Accessed 21 September 2017].

7. Parding, K. M., Liepert, B. G., Hinkelman, L. M., Ackerman, T. P., Dagestad, K. F. and Olseth, J. A., 2016. Influence of synoptic weather patterns on solar irradiance variability in northern Europe. Journal of Climate, 29(11), pp. 4229‒4250. DOI: 10.1175/JCLI-D-15-0476.1.

8. Liu, Y., Zhao, N., Vanos, J.K. and Cao, G., 2017. Effects of synoptic weather on ground-level PM 2.5 concentrations in the United States. Atmospheric Environment, 148, pp. 297‒305. DOI: 10.1016/j.atmosenv. 2016.10.052.

9. Jing, P., O'Brien, T., Streets, D.G. and Patel, M., 2016. Relationship of ground-level ozone with synoptic weather conditions in Chicago. Urban Climate, 17, pp. 161‒175. DOI: 10.1016/j.uclim.2016.08.002.

10.  Zhang, H., Wang, Y., Hu, J., Ying, Q. and Hu, X. M., 2015. Relationships between meteorological parameters and criteria air pollutants in three megacities in China. Environmental research, 140, pp. 242‒254.DOI: 10.1016/j.envres.2015.04.004.

11. Babak, V., Mokiychuk, V., Zaporozhets, A. and Redko, O., 2016. Improving the efficiency of fuel combustion with regard to the uncertainty of measuring oxygen concentration. Eastern-European Journal of Enterprise Technologies, 8(84), pp. 54‒59. DOI: 10.15587/ 1729-4061.2016.85408.

12. Babak, V. P., Babak, S. V., Myslovych, M. V., Zaporozhets, A. O. and Zvaritch, V. M., 2018. Provision of Diagnostic Systems for Energy Facilities. Kyiv: Akademperiodyka. DOI:10.15407/akademperiodyka.353.134.

 повний текст / full article

Visitors

6306657
Today
This Month
All days
448
41849
6306657

Guest Book

If you have questions, comments or suggestions, you can write them in our "Guest Book"

Registration data

ISSN (print) 2071-2227,
ISSN (online) 2223-2362.
Journal was registered by Ministry of Justice of Ukraine.
Registration number КВ No.17742-6592PR dated April 27, 2011.

Contacts

D.Yavornytskyi ave.,19, pavilion 3, room 24-а, Dnipro, 49005
Tel.: +38 (056) 746 32 79.
e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
You are here: Home Home EngCat Archive 2018 Contents №5 2018 Environmental safety, labour protection Method of indirect measurement of oxygen concentration in the air